Industries served

Explosion-Proof Equipment for Oil & Gas — Class I Division 1 & 2

Flameproof and increased-safety equipment for upstream, midstream and gas-processing hazardous areas.

Ex Solutions supplies CSA-certified Class I, Division 1 and Division 2 explosion-proof electrical equipment for oil and gas facilities — wellheads, separators, tank batteries, compressor stations and gas-processing plants — where flammable gas and vapour define the hazardous area.

The challenge

Oil and gas sites are dominated by Class I flammable-gas atmospheres, where a single non-compliant fitting can fail an inspection or an audit. Equipment has to carry the right Division and Temperature (T) code for the process, survive weather, vibration and corrosion, and often ship on a tight turnaround for a shutdown.

What we supply

  • Class I Division 1 & 2 flameproof and increased-safety enclosures and instrument housings
  • Explosion-proof LED lighting, floodlights and fixtures with the correct T-code
  • Hazardous-location disconnect switches, control stations and breaker panels
  • Certified cable glands, breather-drains, seals and conduit fittings
  • Custom-modified enclosures (drilled, mounted, kitted) built to your drawing

Recent projects

Work we’ve delivered in this sector

Anonymized for confidentiality — real scope, real scale.

Oil and gas is the classic hazardous-location market: flammable gas and vapour make most of a site a Class I area, split into Division 1 (present under normal operation) and Division 2 (present only under fault conditions). Getting the Division and the Temperature (T) code right for the process is the difference between a fixture that passes inspection and one that gets red-tagged.

What the process demands

We supply certified equipment across the full envelope — wellheads, separators, tank batteries, compressor stations and gas-processing trains: flameproof enclosures and instrument housings, explosion-proof lighting rated to the correct T-code, disconnects and control stations, and the certified glands, seals and breather-drains that make an installation compliant at every boundary.

Turnaround matters

Shutdowns don't wait. Much of our oil & gas work is time-critical — matching an imported or obsolete part to a certified equivalent, confirming factory lead time, and getting a defensible quote back the same day so the order can be placed.

Area classification and equipment selection must be confirmed with your AHJ and a qualified person (QPS) against the Canadian Electrical Code.

Common questions

Do I need Division 1 or Division 2 equipment for an oil & gas site?
It depends on how often the flammable atmosphere is present. Division 1 applies where ignitable concentrations exist under normal operation; Division 2 where they are present only under abnormal conditions. The area classification is set by a qualified person against CEC Section 18 and the facility's classification drawings — confirm the boundary before selecting equipment.
Can you match a US-spec part to a Canadian-certified equivalent?
Yes. A large part of our work is cross-referencing US or imported parts to CSA-certified equivalents that will pass a Canadian inspection, then quoting them. Send the part number and we confirm the equivalent by hand.

Have a Oil & Gas project?

Send us your line list, spec, or drawing. We’ll quote the certified equipment and cross-reference anything you can’t find.